|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
40 Watts SA40-1313 Series Total Power: Input Voltage: # of Outputs: 40 Watts 85-264 VAC Triple Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 47-63 Hz <25 A peak @ 115 VAC; <50 A peak @ 230 VAC, cold start at 25C 1 A max. (RMS) @ 115 VAC; 0.5 A max (RMS) @ 230 VAC 70% typical at full load, nominal line >0.65 Meets FCC 20780 Class B and VDE 0871 Level B Input current Efficiency Power factor EMI filter Special Features * * * * * * * * Low cost Universal input 3" x 5" footprint Built-in EMI filter Low output ripple 100% computerized final testing Overvoltage protection Overload protection Output Maximum power Cross regulation Overshoot Hold-up time Overvoltage protection Safety ground Leakage current Overload protection 40 W convection 2% on output 1; 5% on outputs 2, 3 None 20 ms @ full load, 115 VAC nominal line +5 V trip voltage less than 6.8 V; recycle AC safety ground to reset < 0.5 mA @ 250 VAC, 50 Hz Short circuit protected on all outputs Environmental Operating temperature: 0 to 50C ambient Storage temperature: -40 to 85C Thermal regulation: .04% per C MTBF: >100,000 hours at full load and 25C ambient conditions per MIL-HDBK-217E TUV UL CSA VDE EN CB IEC950 UL1950 CSA22.2-234 VDE0805, IEC 950 60950 certificate and report R9153228 E132002 LR53982C 11774-3336-1164 UL330-132002 / USA Safety 88 America's (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662 AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44(1384) 843-355 ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 SA40-1313 Series Ordering Information Model Number SA40-1313 Output Voltage 5V 12 V -12 V Minimum Load 0.45 A 0.3 A 0A Maximum Load 5A 3A 0.35 A Peak Load1 -- 4.5 A -- Regulation2 Ripple P/P (PARD)3 50 mV 120 mV 120 mV +5%, -4% 5% 10% 1. Peak current lasting <20 seconds. (Maximum Po = 60 W) 2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F capacitor in parallel with 0.1 F capacitor at rated line voltage and load ranges. Pin Assignments Connector SK1-1 SK1-2 SK1-3 SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SA40-1313 Live Pin removed Neutral +12 V +5 V +5 V Common Common -12 V 3.0 (76.2) SK 1 3 2.57 2 (65.2) 1 N L 0.14 (3.5) M1 0.156 (4) DIA (3 places) M2 SK 2 1 2 3 4 5 6 + Mating Connectors AC Input: Molex 09-91-0300 DC Outputs: Molex 09-91-0600 Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm). 3. Mounting holes M1, M2 and M3 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25C unless otherwise stated. 6. For safety purposes, on mounting hole M4 use plastic standoff. 7. Warranty: 1 year 8. Weight: 0.54 lb / 0.25 kg .022 (5.5) M4 M3 4.57 (116.0) 5.0 (127.0) 0.22 (5.5) 1.34 (34.0) 0.12 (3) www.astec.com 89 |
Price & Availability of SA40-1313 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |